WebSep 15, 2024 · CLR activation logging can be enabled system-wide by using an HKEY_LOCAL_MACHINE registry key or a system environment variable. The log will be generated until the registry entry or the environment variable is removed. Alternatively, you can use a user or process-local environment variable to enable logging with a different … WebOct 16, 2012 · MANAGED_BITNESS_MISMATCH: Managed code needs matching platform of sos.dll for proper analysis. Use ‘x64’ debugger. CONTEXT: 0000000021edf390 — (.cxr 0x21edf390) rax=0000000000000000 rbx=000000001e5e1d00 rcx=000000000000412c rdx=000000001e5e1d00 rsi=000007fef7e44730 rdi=0000000000000003 …
Back to 32-bit vs. 64-bit .NET Basics - Hanselman
So yesterday I upgraded another application that's not a 'standard' Web application. It's a generic server application on my live Windows Server based on my LiveReload Web Server. Unlike the other applications this is not really a standalone Web application, but more of a Web 'Runtime' that can be used to host … See more For this to work this 'runtime' .NET Core application needs to be installed on the server and I recently upgraded this application to run on .NET Core 5.0. Today I decided to move it to the live Windows Server. I … See more The moral of this story is simple: Always install the .NET Core Hosting Bundle on a Windows Server. Always, even if you install the SDK afterwards. The bundle has things that you can't get another way onto your server, which is … See more WebJan 26, 2015 · On the Desktop can you open the Action Center on the taskbar > Maintenance > View reliability history > View all problem reports. Right-click on a few of the "Internet Explorer" "Stopped working" errors > View technical details. birds of prey scientific name
Error 1761 occurred at Open Python Session in MYvi.vi
WebOct 18, 2024 · Reference : SSRS 2012 ERROR [IM014] [Microsoft][ODBC Driver Manager] The specified DSN contains an architecture mismatch between the Driver and Application. IIS7 – Running 32-bit and 64-bit ASP.NET versions at the same time on different worker processes. Asp page on IIS 7 on window 7 64 bit. Hoping for your reply. Best Regards, … WebHow do you resolve a bitness mismatch between the DataMiner version and SLWatchdog.exe? If there is a mismatch, perform the steps below: Stop DataMiner. Go to the folder C:\Skyline DataMiner\Tools and run the following files as Administrator: UnRegister DLLs of DataMiner.bat; Unregister DataMiner.bat; Restart the server. WebYou're right in that it has to do with the bits. To manage a data source that connects to a 32-bit driver under 64-bit platform, use c:\windows\sysWOW64\odbcad32.exe. To manage a data source that connects to a 64-bit driver, use c:\windows\system32\odbcad32.exe. If you use the 64-bit odbcad32.exe to configure or remove a DSN that connects to a ... birds of prey silver coins